Gigabit Ethernet Industrial Media Converters
DISCONTINUED – 065-1897TB
For Replacement options see End-of-Life Notifications
The Signamax Gigabit Ethernet Industrial Media Converters are developed to operate at Gigabit Ethernet speeds in harsh industrial environments. This series offers 1000BaseT to 1000BaseSX or LX in singlemode or multimode. Designed to operate in rugged environments with extreme temperature conditions ranging from -40°F to 176°F (-40°C to 80°C).
The compact, plug-and-play style does not require complex user setup but have the manual setting features necessary to adjust to unusual operating conditions. The Gigabit Ethernet converters offer an cost-effective solution for outdoor environments, transportation roadside systems, shop floors, and other harsh environments.
- NEMA TS1/2 Environmental requirements compliant for traffic control equipment
- IEC61000-6-2 EMC Generic Standard Immunity compliant for industrial environment
- UL 1604 Class 1, Division 2 Classified for use in hazardous locations.
- 1000Base fiber optic port available with MM, SM, and WDM SM
- DIP switch configuration for link fault signalling, link down alarm, plus fiber auto/force mode
- Alarms for power failure and port link failure via relay output
- Redundant 24 V DC terminal block power inputs
- Supports DIN-rail or panel mount installations
- APPLICABLE STANDARDS
IEEE 802.3ab 1000BaseT
IEEE 802.3z 1000BaseSX/LX
- PORTS
P/N 065-1897TB: 1 – RJ-45 1000BaseT Auto-MDI/MDIX port plus
1 -1000BaseLX port
- LED STATUS INDICATORS
Per Unit: Power1, Power2, (Green), Fault, LFS
Per Port: 1000BaseT port: Link/Copper, TX, RX 1000BaseSX/LX port: Link/Fiber, TX, RX
- PERFORMANCE
Latency: <4.2 μs
Throughput, per port: @ 1000BaseT 1,488,100 pps (64-byte packets)
- ELECTRICAL CHARACTERISTICS
DC Input Range: 12 to 48 V DC Connected via Redundant Terminal Block
- ENVIRONMENTAL REQUIREMENTS
Operating Temperature: -40°F to 167°F (-40°C to 75°C)
Storage Temperature: -40°F to 185°F (-40°C to 85°C)
Operating Humidity: 5% to 95% (non-condensing)
- PHYSICAL CHARACTERISTICS
Dimensions: 1.97 W” x 4.33” D x 5.31” H (50 mm x 110 mm x 135 mm)
Housing: IP30 protection, metal case. Pre-attached DIN-rail included.
Weight: 1.76 lb (0.8 kg)
- CERTIFICATIONS
NEMA TS1/2 Environmental requirements for traffic control equipment
Safety: UL 1604: Classified for ITE Equipment for use in hazardous locations: Class 1, Division 2 group A, B, C, & D: Temp Code T4A; -25C < Tamb < 74C UL 60950, EN 60950, IEC 60950, IEC 61000-6-2
EMI: FCC; EN61000-6-3
EMS: ESD Standards (EN61000-4-2); Radiated RFI Standards (IEC 61000-4-3); Burst Standards (IEC 61000-4-4); Surge Standards (IEC 61000-4-5); Induced RFI Standards (IEC 61000-4-6); Magnetic Field Standards (IEC 61000-4-8); Voltage Dip Standards (IEC 61000-4-11)
Environmental Test Compliance: Vibration Resistance (IEC 60068-2-6 Fc); Operation/Storage/Transport Shock (IEC 60068-2-27 Ea); Free Fall (IEC 60068-2-32 Ed)
- WARRANTY
Limited Lifetime
Download Specifications (PDF 260 Kb) Revised 04.11.2016
Download User’s Guide (PDF 12Kb) Revised 02.27.2008