Sixteen bays, for up to sixteen 065-11xx series media converters.
Two 42.5 cfm side-mounted fans, plus one fan for each of the two redundant power supplies.
Per Unit: Power 1/Power 2: Power supply on-line
Dimensions: 17.3” L x 10.9” W x 3.5” H (440 mm x 276 mm x 90 mm) 2 standard rack units
Housing: Aluminum & Steel
Weight: Approximately 18.7 lb (8.5 kg), fully loaded
- ENVIRONMENTAL REQUIREMENTS
Operating Temperature: 32°F to 104°F (0°C to 40°C)
Storage Temperature: -13°F to 158°F (-25°C to 70°C)
Relative Humidity: 5% to 95% (non-condensing)
Load-sharing and hot-swappable; 2 supplied as standard equipment.
Power status LED on each power supply, as well as remote status LEDs on front panel. Specifications, each:
Input: 90-240 V AC, 47-63 Hz.
Output: Normal +12 V DC (Min. +11.88 V, Max. +12.12 V, 7.0 Amps)
Total Regulation: +/- 1.0%, Rip. 120 mV, Load 1.0%, Line 0.5%
Overload Protection: All outputs protected against short circuit conditions; automatic recovery
Over-Voltage Protection: Output level exceeding 13.2 Volts causes shutdown; automatic recovery
UL 1950 listed, CE, FCC, ROHS
Limited Lifetime