Field-Installable Modular Plugs

 

 

More Images

 

The Signamax Field-Installable Modular Plugs are designed for termination of distribution cables and equipment cables connecting directly to such terminal and field devices as security cameras, industrial electronics, and for patching in environments where hardened and reliable connections are required. The plugs are equipped to terminate stranded or solid conductor cables, and with the PCB-based plug design, guarantees high-quality termination in the field.

 

TECH TIP FOCUS: DIRECT ATTACH MODEL – What, When, & Where

 

  • Guaranteed performance per ANSI/TIA-568-C.2 & ISO/IEC 11801 specifications
  • 360-degree screen coverage option for overall solid-metal shielding
  • Compatible with all Signamax modular connectors
  • Rated for at least 750 insertion cycles
  • Toolless field termination with PCB-based electrical design
  • Compatible with solid and stranded conductors
  • Easy-to-read T568A/B wiring scheme color-coded label

 

 

  • TRANSMISSION PERFORMANCE

ANSI/TIA-568-C.2: meet category 5e (1-100 MHz), category 6 (1-250 MHz), and category 6A patch cord requirements
IEC/ISO 11801: meet category 5 (1-100 MHz), category 6 (1-250 MHz), and category 6A (1-500 MHz) requirements

  • TRANSMISSION MEDIA

Unscreened (U/UTP) twisted pair
Screened (U/STP, F/UTP, F/STP, S/UTP, S/STP, SF/UTP, SF/STP) twisted pair
Min cable diameter: Cat 6 & 5e – 4 mm (0.16 in) Cat 6A – 6 mm (0.24 in)
Max cable diameter: Cat 6 & 5e – 6 mm (0.24 in) Cat 6A – 8 mm (0.32 in)

  • PLUG TYPE

8P8C (8-position, 8-contact) “RJ45” style

  • ELECTRICAL

Insulation resistance: Min 500 MOhm @ 100 Vdc
Dielectric withstanding voltage:
1,000 Vdc/ac peak contact-to-contact @ 60 Hz for 1 min
1,500 Vdc/ac peak contact-to-screen @ 60 Hz for 1 min (screened only)

  • CONSTRUCTION

Housing:
Housing:
Screened: Zinc-alloy
Unscreened: High-impact, flame-retardant plastic, UL 94V-0
Contact Pin: Phosphor bronze alloy plated with 50 μin of gold
IDC: 110 type, phosphor bronze alloy with 100 μin 100% tin alloy

  • MECHANICAL

Mating Cycle Life: Min 750 cycles
Wiring Scheme: ANSI/TIA-568-C.2: T568A/T568B
ISO/IEC 11801 2nd Ed.: 8-position pin/pair assignment (1-2/3-6/4-5/7-8)
Wire Gauge: 23 to 26 AWG (0.644 mm–0.511 mm) solid or stranded copper conductors

  • DIMENSIONS

1.96” L x 0.54” W x 0.59” H (49.7 mm x 13.8 mm x 15.0 mm)

  • ENVIRONMENTAL CONDITIONS

Operation: 14 °F to 140 °F (-10 °C to 60 °C)
Storage: -40 °F to 158 °F(-40 °C to 70 °C)
Operating RH: 93% Max (non-condensing)

  • COMPLIANCE

ANSI/TIA-568-C.2, IEC 60603-7, FCC Part 68 Subpart F, UL 94V-0

  • APPLICATIONS

Category 5e:
X.21, V.11, S0, ISDN, CSMA/CD 10BASE-T, 100BASE-TX, 100BASE-T4, 100BASE-T2, 1000BASE-T,
10GBASE-T (up to 25 m (82 ft)), TR 4/16/100, 100BASE-VG, ATM LAN 25/51/155, TP-PMD
Category 6:
X.21, V.11, S0, ISDN, CSMA/CD 10BASE-T, 100BASE-TX, 100BASE-T4, 100BASE-T2, 1000BASE-T,
10GBASE-T (up to 55 m (180 ft)), TR 4/16/100, 100BASE-VG, ATM LAN 25/51/155, TP-PMD
Category 6A:
X.21, V.11, S0, ISDN, CSMA/CD 10BASE-T, 100BASE-TX, 100BASE-T4, 100BASE-T2, 1000BASE-T, 10GBASE-T, TR 4/16/100,
100BASE-VG, ATM LAN 25/51/155, TP-PMD

  • WARRANTY

  5-year limited component warranty
10-year Signamax Link/Channel Warranty
15-year Signamax Extended Component Warranty
25-year Signamax Cabling System Warranty

 

 

Download Specifications Revised 07-2023

Download Category 5e Drawing (PDF 3 Mb) Revised 01-17

Download Category 6 Drawing (PDF 3 Mb) Revised 01-17

Download Category 6A Drawing (PDF 3 Mb) Revised 01-17

 

 

Screened Plugs

Part NumberDescriptionAdd to [?] 
KRJS45FT-C5ECategory 5E Screened Field-Installable Modular Plug

Project

KRJS45FT-C6CCategory 6 Screened Field-Installable Modular Plug

Project

KRJS45FT-C6ACategory 6A Screened Field-Installable Modular Plug

Project

Part NumberDescriptionAdd to [?] 
KRJS45DA-C6Category 6 Screened Field-Installable Modular Plug

Project

Note: DA-series is being discontinued and replaced by the new model. Cat 6A & Cat 5E have already been EOL.

 

Unscreened Plugs

Part NumberDescriptionAdd to [?] 
KRJ45FT-C5ECategory 5E Unscreened Field-Installable Modular Plug

Project

KRJ45FT-C6CCategory 6 Unscreened Field-Installable Modular Plug

Project

KRJ45FT-C6ACategory 6A Unscreened Field-Installable Modular Plug

Project