Category 6 Pre-Terminated Trunk Cable Assemblies

 

6L-C6A6L-C6AS

 

More Images

 

Category 6 Pre-terminated Trunk Assemblies help to reduce significantly both time and cost of a category 6 cabling installation. Terminated and tested in a controlled manufacturing environment, cut to the customer pre-ordered lengths, and ready to install in a patch panel, trunk assemblies eliminate all these operations in the field making your job easy and efficient. Trunk cable assemblies can be provided in an unscreened (U/UTP) and screened (F/UTP) versions in either in a jack-to-jack, jack-to-plug, or jack-to-blunt cut configurations to support the widest range of applications. Cables can be used with any field-configurable patch panel (screened assemblies are not compatible with 48U-HDMMP-1R panels only).

 

 

  • Ready-to-use product – cable bundles are ready for installation and require no additional termina-tion operations except the one-ended designs
  • Solid cable and keystone jacks used in the assembly meet and exceed category 6 specifications
  • Pre-tested at the factory per ANSI/TIA-568-C.1 requirements
  • All cable legs are labeled at both ends for easy identification and aligning in the field
  • Each cable bundle is enclosed in a CMR- or CMP-rated mesh sleeve that retains the bundle and pro-tects it during installation
  • Mesh sleeve is fixed by heat-shrink tubing that can be used as an anchor point when cable pulling is needed
  • Compatible with all Signamax field-configurable patch panels (screened cables are not compatible with 48U-HDMMP-1R only)

 

 

  • TRANSMISSION PERFORMANCE

ANSI/TIA-568-C.2: meets or exceeds category 6 (1-250 MHz) permanent link specifications
NOTE: All cable trunks require field testing after installation

  • TRANSMISSION MEDIA

Unscreened 100-Ohm twisted pair (U/UTP)
Screened 100-Ohm twisted pair (F/UTP)

  • JACK TYPE

8p8c (8-position, 8-contact) “RJ45″ style, keystone design

  • WIRING SCHEME

ANSI/TIA-568-C.2: T568B

  • WIRE GAUGE

23 AWG, solid copper

  • ELECTRICAL – JACK

Insulation resistance: min 500 MOhm @ 100 Vdc
Dielectric withstanding voltage: 1,000 Vdc/ac peak contact-to-contact @ 60 Hz for 1 min
Spring wire contact resistance: max 20 mOhm
IDC contact resistance: max 2.5 mOhm
Current rating: see figure

  • ELECTRICAL – CABLE

Spark test: 2,000 ± 250 Vac
Dielectric strength: 2,500 Vdc / 3 seconds
Insulation resistance: min 150 MOhm/km (46 MOhm/kft)
Conductor resistance: max 9.38 Ohm / 100 m (328 ft) @ 20 °C (68 °F)
Resistance unbalance: max 2 %
Capacitance unbalance: max 160 pF / 100 m (328 ft)
Mutual capacitance: max 5,600 pF / 100 m (328 ft)

  • ELECTRICAL – PLUG

Insulation resistance: min 500 MOhm @ 100 Vdc
Dielectric withstanding voltage: 1,000 Vdc/ac peak contact-to-contact @ 60 Hz for 1 min
Contact resistance: max 20 mOhm
Current rating: see figure

  • CONSTRUCTION – JACK

Housing:
unscreened: high-impact thermoplastic, UL94V-0 fire-retardant
screened: zinc-alloy fully shielded, grounding post for 2.5 x 0.5-mm (0.110 x 0.020-in) female disconnect
Jack spring wire: phosphor bronze alloy plated with 50 μin of gold over 70-100 μin of nickel
IDC: 110 type, phosphor bronze alloy with 100-μin 100% tin (Sn) alloy

  • MOUNTING DIMENSIONS – JACK

Unscreened: D 30.00 mm H 19.30 mm W 16.90 mm (D 1.181 in H 0.760 in W 0.665 in)
Screened: D 42.40 mm H 25.80 mm W 16.90 mm (D 1.669 in H 1.016 in W 0.665 in)

  • CONSTRUCTION – CABLE

CONDUCTOR:
Material: bare copper
Size: 23 AWG
Construction:
unscreened: 1/0.560 ± 0.02 mm (1/0.0221 ± 0.001 in)
screened: 1/0.570 ± 0.02 mm (1/0.0224 ± 0.001 in)

INSULATION:
Materia:l CMR- or CMP-rated thermoplastic
Thickness: max average: 0.24 mm (0.010 in), min at any point: 0.18 mm (0.007 in)
Diameter:
unscreened: 1.04 ± 0.06 mm (0.041 ± 0.002 in)
screened: 1.1 ± 0.02 mm (0.04 ± 0.001 in)
Color coding:
blue/white-blue
orange/white-orange
green/white-green
brown/white-brown
Elongation: min 300 %
Tensile: strength min 1.682 kg/mm2 (0.0058 psi)

CENTRAL ELEMENT: CMR- or CMP-rated thermoplastic, cross-shaped
SHEATH:
Material: CMR- or CMP-rated thermoplastic
Diameter:
unscreened: 6.3 ± 0.3 mm (0.25 ± 0.01 in)
screened: 7.8 ± 0.3 mm (0.31 ± 0.01 in)
Color: see ORDERING INFORMATION
Elongation: min 100 %
Tensile strength: min 1.407 kg/mm2 (0.005 psi)
Thickness:
average: 0.50 mm (0.020 in), min at any point: 0.45 mm (0.018 in)
Aging: at 100°C for 168 hrs – min elongation retention: 50 %, min tensile strength retention: 75 %

SCREEN:
PET tape: 0.023 mm (0.0009 in) thickness
Aluminum/PET tape: 0.025 mm (0.0010 in) thickness
Tinned copper drain wire: 0.46 mm (0.018 in) diameter

  • CONSTRUCTION – PLUG

Assembly: FCC Part 68 Subpart F
Housing: UL listed 94V-0 flame retardant polycarbonate
IDC blades: phosphor bronze, min 50 μin of gold plating over 100 μin of nickel in contact area

  • MECHANICAL – JACK

Total contact force: min 800 g for 8 wire leads
Retention force: 50 N (11 lbf) for 60 ± 5 s
Mating cycle life: min 750 cycles

  • MECHANICAL – CABLE

Tensile strength: > 400 N (90 lbf)
Minimum bend radius: 25 mm (1 in)

  • MECHANICAL – PLUG

Retention: 50 N (11 lbf) for 60±5 s
Mating cycle life: min 750 cycles
Tensile strength: ≥ 20 N per wire

  • ENVIRONMENTAL CONDITIONS

Storage: -40 °C – +70 °C (-40 °F – +158 °F)
Operation: -10 °C – +60 °C (+14 °F – +140 °F)
RH (operation): max non-condensing 93 %

  • COMPLIANCE

ANSI/TIA-568-C.2, IEC 60603-7, IEC 61156-6, IEC 60332-1-2, FCC Part 68 Subpart F, UL 94V-0, UL 444, UL 1666

  • APPLICATIONS

X.21, V.11, S0, ISDN, CSMA/CD 10BASE-T, 100BASE-TX, 100BASE-T4, 100BASE-T2, 1000BASE-T, 10GBASE-T (up to 55 m (180 ft)), TR 4/16/100, 100BASE-VG, ATM LAN 25/51/155, TP-PMD

  • WARRANTY

5-year limited component warranty
10-year Signamax Link/Channel Warranty
15-year Signamax Extended Component Warranty
25-year Signamax Cabling System Warranty

 

 

Download Datasheet – Unscreened (PDF 705Kb) Revised 03.08.2011

Download Datasheet -Screened (PDF 662Kb) Revised 03.08.2011

 

 

Part Number Description
6L-C6-JJ-R-FXXX Category 6 6-Leg Trunk Cable, Jack-to-Jack, Unscreened (U/UTP) Cable, CMR
6L-C6-JP-R-FXXX Category 6 6-Leg Trunk Cable, Jack-to-Plug, Unscreened (U/UTP) Cable, CMR
6L-C6-JB-R-FXXX Category 6 6-Leg Trunk Cable, Jack-to-Open, Unscreened (U/UTP) Cable, CMR
6L-C6S-JJ-R-FXXX Category 6 6-Leg Trunk Cable, Jack-to-Jack, Screened (F/UTP) Cable, CMR
6L-C6S-JP-R-FXXX Category 6 6-Leg Trunk Cable, Jack-to-Plug, Screened (F/UTP) Cable, CMR
6L-C6S-JB-R-FXXX Category 6 6-Leg Trunk Cable, Jack-to-Open, Screened (F/UTP) Cable, CMR
For length substitute XXX for length in feet. Minimum length is 10 ft. Maximum length is 295 ft.
Unscreened cable color is blue. Screened cable is gray. Other colors are available.
Standard cable is straight-cut for either left or right cable exit. Staggered-cut cables are available.
For plenum-rated (CMP) cable substitute P for R in P/N.