Pre-Terminated Fiber Optic Cassettes

More Images

 

  • Factory tested and terminated fiber with documentation
  • Interchangeable rear adapter plates for multiple entry positions
  • Part of CORE12 application for 10 or 40 GB Ethernet Standard
  • LGX front adapter with 6 or 12 ports and LC or SC Adapters
  • Made & assembled in the USA

 

 

  • TRANSMISSION PERFORMANCE

ANSI/TIA/EIA-568-C.3: Insertion and return loss (100% tested)
Durability:
OM4/OM5: < 0.2 dB change (per EIA-455-21A), 1000 re-mates
SM: < 0.3 dB change (per EIA-455-21A), 500 re-mates
Return loss:
OM4/OM5: ≤ 20 dB
SM: ≤ 55 dB (8º angle polish)
Insertion loss:
OM4/OM5: Typical 0.20 dB (all fibers), Max 0.50 dB (single fiber)
SM: Typical 0.25 dB (all fibers), Max 0.75 dB (single fiber)
MTP Elite® Performance:
OM4/OM5: Typical 0.10 dB (all fibers), Max 0.35 dB (single fiber)
SM: Typical 0.05 dB (all fibers), Max 0.05 dB (single fiber)

  • CONSTRUCTION

Cassette: 0.8 mm (GA.20) aluminum alloy, black epoxy powder finish
Front & Rear Adapter Plate: 1.5 mm (GA.15) aluminum alloy, black epoxy powder finish
Push Pins: Polycarbonate/nylon
Adapter Housing: High-Impact thermoplastic, UL94V-0 fire-retardant
Mounting Screws: Steel, black oxide finish

  • CAPACITY

Front Adapter Plate:
3QH: LGX, three DX SC or 3 QX LC adapters
6QH: LGX, six DX SC or 3 QX LC adapters

  • FORMATS

Blank: covers unused cable entry ports
1 – MTP: one universal (A or B) black flanged MTP adapter
2 – MTP: two universal (A or B) black flanged MTP adapters

  • DIMENSIONS

Box Only: 5.12” D x 4.13” W x 1.14” H (130 mm x 105 mm x 29 mm)
Front Adapter Plate: 5.12” D x 4.13” W x 1.14” H (130 mm x 105 mm x 29 mm)
Rear Adapter Plates: 1.58” L x 1.42” W (42 mm x 27 mm)

  • ENVIRONMENTAL CONDITIONS

Operating Temperature: -40 to 176 °F (-40 to 80 °C)
Operating RH: 93% Max (non-condensing)

  • WARRANTY

5-year Limited Component
10-year Signamax Base Trunk
15-year Signamax Extended Component
25-year Signamax Cabling System

 

Download Specifications (PDF 678Kb) Revised 12.2018

Download Instructions (PDF 1.4MB) Revised 04.2018

 

Part NumberDescriptionAdd to [?] 
FCM-12190-M4A12-Fiber 1 MTP OM4 LC Type A, LGX Cassette

Project

FCM-24290-M4A24-Fiber 2 MTP OM4 LC Type A, LGX Cassette

Project

FCM-12190-M5A12-Fiber 1 MTP OM5 LC Type A, LGX Cassette

Project

FCM-24290-M5A24-Fiber 2 MTP OM5 LC Type A, LGX Cassette

Project

FCM-12190-SMA12-Fiber 1 MTP SM LC Type A, LGX Cassette

Project

FCM-24290-SMA24-Fiber 2 MTP SM LC Type A, LGX Cassette

Project

For additional customization, configure your own part number:

 

ORDERING CONFIGURATION

MPO
CASSETTE

 

FIBER
COUNT

No. of
MTP

CONNECTOR
TYPE

 

FIBER
TYPE

METHOD

FCM

 _

XX

XX

XX

X

    08: 8 fiber 1: MTP 90: LC   M4: OM4 A
    12: 12 fiber 2: MTP 40: SC   M5: OM5 B
    16: 16 fiber   9A: LC APC   SM: Singlemode C
    24: 24 fiber   4A: SC APC