10/100 to 100FX Industrial Media Converters

DISCONTINUED – 065-1800TB, 065-1810TB, 065-1820TB, 065-1820EDTB, 065-1820XLDTB,
065-1876ATB, 065-1876BTB, 065-1876AEDTB, & 065-1876BEDTB

For Replacement options see End-of-Life Notifications

 
065-1800TB065-1876ATB
 

 

The Signamax 10/100 to 100FX Industrial Media Converter was developed to operate in harsh industrial environments that require rugged equipment that can operate in severe temperature extremes. These media converters are an affordable solution for outdoor environments, transportation roadside systems, shop floors, and other harsh environments where consistent operation at temperature extremes of -40°F to 176°F (-40°C to 80°C) is necessary. These media converters are compact, plug-and-play devices that do not require complex user setup, but also have the manual setting features necessary to adjust to unusual operating conditions.

 

 

  • Meets NEMA TS1 Environmental Requirements for Traffic Control Equipment.
  • Meets IEC61000-6-2 EMC Generic Standard Immunity for Industrial Environment.
  • UL 1604 Class 1, Division 2 Classified for use in hazardous locations.
  • RJ-45 Port Auto-Negotiates 10/100Mbps & Full/Half-Duplex Mode, with Auto-MDIX
  • 100FX Port Available with Multimode, Singlemode, and WDM Singlemode.
  • DIP Switch Configuration for Link Fault Signaling/Link Down Alarm, Plus Speed/Duplex Mode
  • Non-Blocking Store-and-Forward Mechanism for Full Wire-Speed Performance
  • Supports 2K MAC Addresses.
  • Broadcast Storm Filtering
  • Back-Pressure and IEEE 802.3x Compliant Flow Control
  • Alarms for Power Failure and Port Link Failure via Relay Output.
  • Redundant 24V DC Terminal Block Power Inputs
  • Supports DIN-Rail or Panel Mount Installations

 

 

  • APPLICABLE STANDARDS

IEEE802.3 10BaseT
IEEE802.3u 100BaseTX / 100BaseFX
IEEE802.3x Flow Control and Back pressure

  • PORTS

1 twisted-pair 10/100BaseT/TX Auto MDI/MDI-X, Auto-Negotiation Function port (all models)
PLUS
1 100Base FX port with ST/MM, 2 km span (Model 065-1800TB)
OR
1 100Base FX port with SC/MM, 2 km span (Model 065-1810TB)
OR
1 100Base FX port with SC/SM, 20 km span (Model 065-1820TB)
OR
1 100Base FX port with SC/SM, 40 km span (Model 065-1820EDTB)
OR
1 100Base FX port with SC/SM, 75 km span (Model 065-1820XLDTB)
OR
1 100Base FX port with WDM A SC/SM simplex, 20 km span (Model 065-1876ATB)
OR
1 100Base FX port with WDM B SC/SM simplex, 20 km span (Model 065-1876BTB)
OR
1 100Base FX port with WDM A SC/SM simplex, 40 km span (Model 065-1876AEDTB)
OR
1 100Base FX port with WDM B SC/SM simplex, 40 km span (Model 065-1876BEDTB)

  • LED STATUS INDICATORS

Per Unit: Power1 (Green), Power2 (Green). Fault, LFS
Per Port: 10/100BaseT/TX port: 100 Mbps Speed, Link/Activity, FDX/COL; 100BaseFX port: Link/Activity, FDX/COL

  • PERFORMANCE

Latency: < 4.2 µs (LIFO)
Throughput @ 100Base: 148,810 pps (64-byte packets)

  • FIBER INTERFACE

Multimode Models:

Type: LED
Wavelength: 1300 nm nominal (1270 nm maximum, 1380 nm minimum)
Maximum Output Power: – 14.0 dBm
Minimum Output Power: – 20.0 dBm
Sensitivity: – 33.0 dBm
Maximum Input Power: – 8.0 dBm
Link Power Budget: 13.0 dB

Singlemode Models:

Type: MQW Laser
Wavelength:
P/N 065-1820TB/1820EDTB: 1300 nm nominal (1260 nm maximum, 1360 nm minimum)
P/N 065-1820XLDTB: 1300 nm nominal (1270 nm maximum, 1350 nm minimum)
Transmit Wavelength:
P/N 065-1876ATB/1876AEDTB: 1310 nm nominal (1260 nm maximum, 1360 nm minimum)
P/N 065-1876BTB/1876BEDTB: 1550 nm nominal (1480 nm maximum, 1580 nm minimum)
Receive Wavelength:
P/N 065-1876ATB/1876AEDTB: 1550 nm nominal (1490 nm maximum, 1600 nm minimum)
P/N 065-1876BTB/1876BEDTB: 1310 nm nominal (1260 nm maximum, 1360 nm minimum)
Maximum Output Power:
P/N 065-1820TB: – 7.0 dBm
P/N 065-1820EDTB: – 5.0 dBm
P/N 065-1820XLDTB: + 3.0 dBm
P/N 065-1876ATB/1876BTB: – 8.0 dBm
P/N 065-1876AEDTB/1876BEDTB: – 3.0 dBm
Minimum Output Power:
P/N 065-1820TB:- 15.0 dBm
P/N 065-1820EDTB: – 12.0 dBm
P/N 065-1820XLDTB: – 3.0 dBm
P/N 065-1876ATB/1876BTB: – 14.0 dBm
P/N 065-1876AEDTB/1876BEDTB: – 8.0 dBm
Sensitivity:
P/N 065-1820TB: – 34.0 dBm
P/N 065-1820EDTB: – 35.0 dBm
P/N 065-1820XLDTB: – 37.0 dBm
P/N 065-1876ATB/1876BTB/1876AEDTB/1876BEDTB: – 33.0 dBm
Maximum Input Power:
P/N 065-1820TB:- 7.0 dBm
P/N 065-1820EDTB: – 5.0 dBm
P/N 065-1820XLDTB: – 0.0 dBm
P/N 065-1876ATB/1876BTB/1876AEDTB/1876BEDTB: – 3.0 dBm
Link Power Budget:
P/N 065-1820TB: 19.0 dB
P/N 065-1820EDTB: 23.0 dB
P/N 065-1820XLDTB: 34.0 dB
P/N 065-1876ATB/1876BTB: 19.0 dB
P/N 065-1876AEDTB/1876BEDTB: 25.0 dB

  • ELECTRICAL CHARACTERISTICS

DC Input Range: 12 to 48 V DC Connected via Redundant Terminal Block

  • ENVIRONMENT REQUIREMENTS

Operating Temperature: -40°F to 176°F (-40°C to 80°C)
Storage Temperature: -50°F to 200°F (-45°C to 93°C)
Operating Humidity: 10 to 95% (non-condensing)

  • PHYSICAL CHARACTERISTICS

Dimensions: 1.97 in. x 5.35 in. x 4.33 in., W x H x D (50 mm x 136 mm x 110 mm)
Housing: IP-30 protection, metal case
Weight: 1.76 lb (0.8 kg.)

  • CERTIFICATIONS

NEMA TS1/2 Environmental requirements for traffic control equipment

SAFETY: UL 1604: Classified for ITE Equipment for use in hazardous locations: Class 1, Division 2 group A, B, C, & D: Temp Code T4A; -25C < Tamb < 74C UL 60950, EN 60950, IEC 60950, IEC 61000-6-2
EMI: FCC, EN55022 (CISR22 Class A), EN55024 (CISPR24 Class A), EN-6100-4-4, EN6100-4-5, EN6100-4-6

Environmental Test Compliance: Vibration Resistance (IEC 60068-2-6): 5G@150Hz; Criterion 3; Operation/Storage/Transport Shock (IEC 60068-2-27):
25G @ 11ms (Half-Sine Shock Pulse; Operation), 50G @ 11ms (Half-Sine Shock Pulse: Storage/Transport), Free Fall (IEC 60068-2-32): Free Fall: 1M (3.281 ft.); ESD Standards (IEC 61000-4-2): Enclosure Contact: +/- 4kV; Criteria B; Enclosure Air: +/- 8kV; Criteria B; Radiated FRI Standards (IEC 61000-4-3): Enclosure Ports: +/- 4kV @ 2.5kHz; Criteria B; Burst Standards (IEC 61000-4-4): Enclosure Ports: 10V/m, 80 to 1000MHz; Criteria A; D.C. Power Ports: +/- 4kV; Criteria B; A.C. Power Ports: +/- 4kV; Criteria B; Surge Standards (IEC 61000-4-5): Signal Ports: +/- 1kV Line-to-earth; Criteria B;D.C. Power Ports: +/- 0.5kV Line-to-earth; Criteria B;A.C. Power Ports: +/- 2kV; Line-to-earth; Criteria B; Induced RFI Standards (IEC 61000-4-6): Signal Ports: 10v@ 0.15 – 80 MHz; Criteria A; DC Power Ports: 10v@ 0.15 – 80 MHz; Criteria A; AC Power Ports: 10v@ 0.15 – 80 MHz; Criteria A; Earth Ground Ports: 10v@ 0.15 – 80 MHz; Criteria A; Magnetic Field Standards (IEC 61000-4-8): Enclosure Ports: 30A/m@ 50, 60Hz; Criteria A; Voltage Dip Standards (IEC 61000-4-11): AC Power Ports: 30% Reduction for 0.5 period; Criteria B

  • WARRANTY

Limited Lifetime

 

 

Download Specifications (PDF126 Kb) Revised 09.29.2008

Download User’s Guide (PDF282 Kb) Revised 02.16.2007