10/100 Industrial Unmanaged Switches

DISCONTINUED – 065-74091FXSCTB, 065-74091FXSTTB, 065-74082FXTB, 065-74082FXSMTB,
065-74084FXTB, & 065-74084FXSMTB

For Replacement options see End-of-Life Notifications

 

065-740xxTB-composite

 

The Signamax 065-74xx series 5-Port, 8-Port, & 9-Port 10/100 Unmanaged Industrial Switches have been developed to operate in harsh industrial environments that require rugged equipment that can operate in severe temperature extremes. These switches are an affordable solution for outdoor environments, transportation roadside systems, shop floors, and other harsh environments where consistent operation at temperature extremes of -40°F to 167°F (-40°C to 75°C) is necessary. These unmanaged switches are compact, plug-and-play devices that do not require complex user setup.

 

 

  • Meets NEMA TS1 and TS2 Environmental Requirements for Traffic Control Equipment.
  • Meets IEC61000-6-2 EMC Generic Standard Immunity for Industrial Environment.
  • UL 1604 Class 1, Division 2 Classified for use in hazardous locations.
  • 10/100 Mbps – Full/Half Duplex, Auto-Negotiation, Auto-MDIX.
  • 2048 MAC Addresses, 768K bits Buffer Memory, Full Wire-Speed Performance.
  • Alarms for Power Failure and Port Link Failure via Relay Output.
  • Redundant 1.5 Amp rated, 24 V DC Terminal Block Power Inputs.
  • Supports DIN-rail or Panel Mount installations.

 

 

  • APPLICABLE STANDARDS

IEEE802.3 10BaseT
IEEE802.3u 100BaseTX / 100BaseFX
IEEE802.3x Flow Control and Back pressure

  • FIXED PORTS

All Models:
4 (models 065-74084FXTB and 065-74084FXSMTB), 5 (model 065-7405TB), 6 (models 065-74082FXTB and 065-
74082FXSMTB), or 8 (models 065-7408ATB, 065-74091FXSCTB, and 065-74091FXSTTB) twisted pair ports meeting IEEE 802.3
10BaseT & IEEE 802.3u 100BaseTX standard specifications; Category 5 or better cable, 100 meters maximum distance for 100BaseTX,
Category 3 or better cable, 100 meters maximum distance for 10BaseT. Auto MDI/MDI-X and Auto-Negotiation Function supported.
Models 065-74091FXSCTB, 065-74091FXSTTB, and 065-74091FXSMTB: 1 100BaseFX port, with SC Multimode, 2 km Span
(model 065-74091FXSCTB) or ST Multimode, 2 km Span (model 065-74091FXSTTB) or SC Singlemode, 15 km Span (model 065-
74091FXSMTB) connectors.

Models 065-74082FXTB and 065-74082FXSMTB:
2 100BaseFX ports, with SC Multimode, 2 km Span (model 065-74091FXSCTB)
or ST Multimode, 2 km Span (model 065-74091FXSTTB) or SC Singlemode, 15 km Span (model 065-74091FXSMTB) connectors.

Models 065-74084FXTB and 065-74084FXSMTB:
4 100BaseFX ports, with SC Multimode, 2 km Span (model 065-74084FXTB) or
SC Singlemode, 15 km Span (model 065-74084FXSMTB) connectors.

  • LED STATUS INDICATORS

Per Switch: Power Status 1 & 2 (green); Fault (red)
Per 10/100BaseT/TX Port and 100BaseFX Port (where equipped): Link/Activity (green), 100 Mbps speed (amber)

  • PERFORMANCE

Latency: <7.1 μs (LIFO).
Throughput: 14,880 pps for 10 Mbps, 148,800 pps for 100 Mbps (64-byte packets)
Switch Fabric Speed: 24.0 Mbps (non-blocking, wire speed performance)
MAC Address Capacity: 2 K MAC addresses
Buffer Memory: 768 Kb
Switch Architecture: Store and Forward

  • POWER INPUT REQUIREMENTS

Redundant 10 to 48 Volts DC Terminal Block. Optional hardened power supply sold separately.

  • POWER CONSUMPTION:

12 V DC @ 0.99 A, 24 V DC @ 0.55 A, 48 V DC @ 0.39 A; 18.72 Watts Maximum.

  • INSTALLATION

Included DIN-rail mount. Optional wall mounting bracket available by special order.

  • ENVIRONMENTAL CHARACTERISTICS

Operating Temperature: -40°F to 167°F (-40°C to 75°C)
Storage Temperature: -50°F to 200°F (-45°C to 93°C)
Operating Humidity: 10 to 95% (non-condensing)

  • PHYSICAL CHARACTERISTICS

Dimensions: 1.97 in. x 5.35 in. x 4.33 in., W x H x D (50 mm x 136 mm x 110 mm)
Weight: 1.76 lb (0.8 kg.)
Housing: IP30 protection, metal case

  • CERTIFICATIONS

ESD Standards (IEC 61000-4-2): Enclosure Contact: + / – 4KV; Criteria B; Enclosure Air: + / – 8KV; Criteria B

Radiated FRI Standards (IEC 61000-4-3): Enclosure Ports: 10V/m, 80 to 1000MHz; Criteria A

Burst Standards (IEC 61000-4-4):
Enclosure Ports: + / – 4KV @ 2.5 KHz; Criteria B;
D.C. Power Ports: + / – 4KV; Criteria B;
A.C. Power Ports: + / – 4KV; Criteria B

Surge Standards (IEC 61000-4-5):
Signal Ports: + / – 1KV; Line-to-earth; Criteria B
D.C. Power Ports: + / – 0.5KV; Line-to-earth; Criteria B
A.C. Power Ports: + / – 2KV; Line-to-earth; Criteria B

Induced RFI Standards (IEC 61000-4-6):
Signal Ports: 10V @ 0.15 – 80MHz; Criteria A
D.C. Power Ports: 10V @ 0.15 – 80MHz; Criteria A
A.C. Power Ports: 10V @ 0.15 – 80MHz; Criteria A
Earth Ground Ports: 10V @ 0.15 – 80MHz; Criteria A

Magnetic Field Standards (IEC 61000-4-8): Enclosure Ports: 30A/m @ 50, 60Hz; Criteria A
Voltage Dip Standards (IEC 61000-4-11): A.C. Power Ports: 30% Reduction for 0.5 period; Criteria B

Environmental Test Compliance:
(IEC 60068-2-6) Vibration Resistance: 5G @ 150Hz; Criterion 3 (Operation/Storage/Transport)
(IEC 60068-2-27) Shock: 25G @ 11ms (Half-Sine Shock Pulse; Operation); 50G @ 11ms (Half-Sine Shock Pulse; Storage/Transport)
(IEC 60068-2-32) Free Fall: 1M (3.281ft.)

NEMA TS1/2 Environmental Requirements for Traffic Control Equipment

  • EMISSIONS

FCC Class A, Part 15; CE EN6100-6-2, CE EN6100-6-3

  • SAFETY

UL 1604: Classified for ITE Equipment for use in hazardous locations: Class 1, Division 2 group A, B, C, & D:
Temp Code T4A; -25C < Tamb < 74C
UL 60950, EN 60950, IEC 60950, IEC 61000-6-2

  • WARRANTY

Five years

 

 

Download Specifications (PDF 2Mb) Revised 04.26.2012

Download User’s Guide (PDF 407Kb) Revised 08.01.2008